1.0 Setting Up the Linksys SPA-9000
To set up the Linksys SPA-9000:
1.1 Run a Cat 5 cable from a POE/Ethernet hub to the Internet port on the SPA-9000.
1.2 Run a second Cat 5 cable from a PoE/Ethernet hub to the Ethernet port on the SPA-9000.
1.3 Plug in a computer/laptop, a Linksys phone, and a CyberData speaker to the PoE/Ethernet
hub.
1.4 Adjust the IP address of the computer/laptop so that it is on the same network as the SPA-9000
(192.168.0.X).
1.5 Enter the IP address of SPA-9000 in a browser (192.168.0.1/admin/voice/advanced).
1.6 Under Vo ic e click on the SIP tab.
1.7 In the PBX parameters section, select WAN.
1.8 Click on submit all changes.
1.9 Click on the Router tab.
1.10 Click on the WAN Setup tab.
1.11 From the Connection Type drop-down menu, select Static IP.
1.12 In the Static IP section, fill out the IP address, Netmask and Gateway fields.
1.13 Go to Router => LAN Setup and set an IP address that is on a different subnet than the WAN
address.
1.14 Select submit all changes.
2.0 Setting up the Speaker for SIP
To set up the speaker for SIP:
2.1 Pull up the web-based configuration for the speaker and click on SIP settings.
2.2 Enter the username (usually an extension number) and password.
2.3 Enter the static IP address that is in the WAN setup of the SPA-9000 as the SIP server address.
2.4 Change the remote SIP port to 6060.
2.5 Save the settings and reboot the speaker.
2.6 Send a page to the speaker by entering the extension number (username) of the speaker at the
dial-tone.
Setting Up the CyberData Speakers
with Linksys SPA-9000
Zobrazit stránku 0
1 2 3 4

Shrnutí obsahu

Strany 1

1.0 Setting Up the Linksys SPA-9000To set up the Linksys SPA-9000:1.1 Run a Cat 5 cable from a POE/Ethernet hub to the Internet port on the SPA-9000.

Strany 2

Figure 1. Linksys—SIP Diagram3.0 Setting up the Speaker for MulticastTo set up the speaker for Multicast:3.1 If you are using CyberData speakers as

Strany 3 - ● Username (extension number)

3.9 Select page groups as the page target (see Figure 2).Figure 2. Linksys—Multicast Diagram4.0 Setting up the Paging ServerTo set up the paging serv

Strany 4

Figure 3. Linksys—Paging Server Diagram4.3 Go to the web configuration for the speaker and select MGROUPS.4.4 In the MGROUPS Setup page, match the mu

Komentáře k této Příručce

Žádné komentáře