Installing the VoIP Outdoor Intercom with Keypad
Intercom Setup
Operations Guide 930809M CyberData Corporation
65
2.4.13 Configure the Door Strike Relay
The Door Strike Relay (DSR) is a network device designed to control an electronic door strike. The
DSR is meant to be used as a replacement for (or an addition to) the on-board relay. In addition to
being a drop-in 12 Amp relay, the DSR can monitor and record when the door is open or closed.
The DSR can be configured to trigger in the following ways: on the entry of a DTMF code, during
different call events, manually through the web interface, or by using a Windows application.
1. Click on the DSR menu button to open the DSR page (Figure 2-30).
Figure 2-30. DSR Page